Scaled event floor plans built to pass Fire Marshal review.
Deterministic IFC Chapter 31, Table 1004.5, and NFPA 101 egress checks with instant 3-sheet
architectural PDF and AutoCAD DXF submittal export.
IFC 2018 / 2021 / 2024NFPA 10111"x17" PDF + DXF
Governing Occupant Load160 occ160 area / 96 seated
Exits Provided vs Required2 / 2 exits144" / 144" total width
Max Egress Travel Distance48 ftMax allowed 100 ft
Audit StatusPASS9/9 checks passed
FP-101/60'-0" x 40'-0"/Scale 1/8" = 1'-0"
What goes into the 3-sheet Fire Marshal Submittal Packet
Every paid export produces a print-ready 11"x17" architectural PDF set plus layered CAD and
rental equipment schedules.
SHEET FP-101
Scaled Floor Plan
True architectural scale (1/8" = 1'-0" or 1/16" = 1'-0") with graphic scale bar, North arrow, dimensioned
perimeter, exit opening widths, worst-case egress travel path, 75-ft fire extinguisher
coverage rings, and 20-ft generator or cooking setbacks.
SHEET FP-102
Code Compliance & Occupant Schedule
Full 9-point deterministic compliance ledger citing IFC Chapter 31, IFC Table 1004.5, and
NFPA 101. Lists gross vs. net area deductions, governing occupant load, required vs.
provided exit count, total exit width, remote exit diagonal separation, and pinch-point
aisle clearance.
SHEET FP-103
Submittal Checklist & Equipment Schedule
Jurisdiction-specific AHJ submittal checklist, NFPA 701 flame-retardancy certificate
reminder, and itemized table, chair, booth, exit sign, ADA space, and 2A:10BC extinguisher
quantities formatted for permit reviewers and tent crews.
.DXF
AutoCAD R2000 Layered Drawing
7 architectural and life-safety layers drawn at 1:1 inches for venues, CAD drafters, or
a local PE/RA to review and seal.
.CSV
Itemized Equipment Schedule
Spreadsheet-ready count of tables, seating capacity, stages, bars, exit signage, ADA
wheelchair spaces, and fire extinguishers.
Watch the 49-second Fire Marshal submittal walkthrough
See a 40x60 banquet tent drafted from scratch, audited across all 9 IFC and NFPA 101
checks, and exported as an 11x17 3-sheet PDF plus 7-layer AutoCAD DXF.
Draft and run live compliance checks for free. Unlock clean, unwatermarked permit packets
per event or unlimited with Pro Permit Studio. Every purchase is backed by a 30-day 100%
money-back guarantee.
Single Event Packet
Fire Marshal Submittal Packet
$39one-time per floor plan
Complete unwatermarked 3-sheet architectural permit submittal packet, CAD DXF, and equipment CSV for this event.
30-day 100% money-back guarantee: if your packet does not fit your submittal workflow, request
a full refund anytime within 30 days on the refund page.
Verified Municipal Permit Thresholds
Local fire departments enforce different tent square-footage triggers, adopted code
editions, and PE/RA stamp rules. Select a city to inspect its requirements or load its
rules directly into the studio.
Most US Fire Marshals accept scaled event floor plans prepared by event planners, tent
contractors, or venue managers when accompanied by occupant load math and NFPA 701 flame
certificates. However, EgressCAD is drafting and compliance-checking software and does not
affix a licensed Professional Engineer (PE) or Registered Architect (RA) seal. In the 7
verified jurisdictions below, local rules mandate a state-licensed PE or RA stamp above
specified size or occupant thresholds. You can export the EgressCAD .DXF and hand it directly to a local engineer or architect to
review and seal: