Scaled event floor plans built to pass Fire Marshal review.

Deterministic IFC Chapter 31, Table 1004.5, and NFPA 101 egress checks with instant 3-sheet architectural PDF and AutoCAD DXF submittal export.

IFC 2018 / 2021 / 2024 NFPA 101 11"x17" PDF + DXF
Governing Occupant Load 360 occ 360 area / 40 seated
Exits Provided vs Required 3 / 2 exits 240" / 54" total width
Max Egress Travel Distance 65 ft Max allowed 250 ft
Audit Status PASS 9/9 checks passed
FP-101 / 90'-0" x 60'-0" / Scale 1/8" = 1'-0"
90'-0"60'-0"B1B2B3B4B5B6B7B8B9B10B11B12B13B14B15B16B17B18B19B20FEFE-1FEFE-2ADAADAADAADAADAADA65 ft travel[EXIT]96"[EXIT]72"[EXIT]72"N010'20'

What goes into the 3-sheet Fire Marshal Submittal Packet

Every paid export produces a print-ready 11"x17" architectural PDF set plus layered CAD and rental equipment schedules.

SHEET FP-101

Scaled Floor Plan

True architectural scale (1/8" = 1'-0" or 1/16" = 1'-0") with graphic scale bar, North arrow, dimensioned perimeter, exit opening widths, worst-case egress travel path, 75-ft fire extinguisher coverage rings, and 20-ft generator or cooking setbacks.

SHEET FP-102

Code Compliance & Occupant Schedule

Full 9-point deterministic compliance ledger citing IFC Chapter 31, IFC Table 1004.5, and NFPA 101. Lists gross vs. net area deductions, governing occupant load, required vs. provided exit count, total exit width, remote exit diagonal separation, and pinch-point aisle clearance.

SHEET FP-103

Submittal Checklist & Equipment Schedule

Jurisdiction-specific AHJ submittal checklist, NFPA 701 flame-retardancy certificate reminder, and itemized table, chair, booth, exit sign, ADA space, and 2A:10BC extinguisher quantities formatted for permit reviewers and tent crews.

.DXF
AutoCAD R2000 Layered Drawing

7 architectural and life-safety layers drawn at 1:1 inches for venues, CAD drafters, or a local PE/RA to review and seal.

.CSV
Itemized Equipment Schedule

Spreadsheet-ready count of tables, seating capacity, stages, bars, exit signage, ADA wheelchair spaces, and fire extinguishers.

Watch the 49-second Fire Marshal submittal walkthrough

See a 40x60 banquet tent drafted from scratch, audited across all 9 IFC and NFPA 101 checks, and exported as an 11x17 3-sheet PDF plus 7-layer AutoCAD DXF.

Watch on YouTube

Simple submittal pricing

Draft and run live compliance checks for free. Unlock clean, unwatermarked permit packets per event or unlimited with Pro Permit Studio. Every purchase is backed by a 30-day 100% money-back guarantee.

Single Event Packet

Fire Marshal Submittal Packet

$39 one-time per floor plan

Complete unwatermarked 3-sheet architectural permit submittal packet, CAD DXF, and equipment CSV for this event.

  • Unwatermarked 11"x17" 3-sheet PDF (FP-101 Floor Plan, FP-102 Compliance Ledger, FP-103 Checklist)
  • True architectural scale (1/8"=1'-0" or 1/16"=1'-0") with graphic scale bar & North arrow
  • AutoCAD R2000 (.DXF) layered drawing (7 architectural/fire layers at 1:1 inches)
  • Itemized rental & safety equipment schedule (.CSV) + 30-day 100% refund guarantee
Unlimited Events

Pro Permit Studio

$49 per month · cancel anytime

Built for tent rental companies, venues, and event producers filing multiple floor plans each month.

  • Unlimited unwatermarked 3-sheet Fire Marshal PDF, DXF & CSV exports across all saved plans
  • Custom company name in the architectural sheet title block
  • Saved multi-event dashboard under your email sign-in
  • Self-serve Stripe billing portal (cancel or update card anytime) + 30-day guarantee
30-day 100% money-back guarantee: if your packet does not fit your submittal workflow, request a full refund anytime within 30 days on the refund page.

Verified Municipal Permit Thresholds

Local fire departments enforce different tent square-footage triggers, adopted code editions, and PE/RA stamp rules. Select a city to inspect its requirements or load its rules directly into the studio.

Browse all 40 US cities
Austin, TX Standard AHJ
Austin Fire Department - Fire Prevention & Special Events Division
Enclosed Tent
> 400 sq ft
Open Canopy
> 700 sq ft
Code
2024 IFC with Austin Local Amendments
Dallas, TX Standard AHJ
Dallas Fire-Rescue Department - Inspection & Life Safety Education Division
Enclosed Tent
> 400 sq ft
Open Canopy
> 700 sq ft
Code
2021 Dallas Fire Code (2021 IFC with Local Amendments)
Houston, TX Standard AHJ
Houston Fire Department - Life Safety Bureau (Fire Marshal's Office)
Enclosed Tent
> 1200 sq ft
Open Canopy
> 1200 sq ft
Code
2021 Houston Fire Code (2021 IFC with LSB Standard No. 22 Amendments)
San Antonio, TX Standard AHJ
San Antonio Development Services Department & Fire Prevention Division
Enclosed Tent
> 750 sq ft
Open Canopy
> 1200 sq ft
Code
2024 San Antonio Fire Code (2024 IFC with Chapter 11 Local Amendments)
Los Angeles, CA Standard AHJ
Los Angeles Fire Department (LAFD) - Public Assemblage Unit & LADBS
Enclosed Tent
> 400 sq ft
Open Canopy
> 700 sq ft
Code
California Fire Code (2022 CFC) with Los Angeles Fire Code Amendments
San Francisco, CA Standard AHJ
San Francisco Fire Department (SFFD) - Bureau of Fire Prevention
Enclosed Tent
> 400 sq ft
Open Canopy
> 700 sq ft
Code
2025 San Francisco Fire Code (California Fire Code with SF Amendments)
San Diego, CA Standard AHJ
San Diego Fire-Rescue Department (SDFD) - Community Risk Reduction / Special Events
Enclosed Tent
> 400 sq ft
Open Canopy
> 700 sq ft
Code
2022 California Fire Code with City of San Diego Local Amendments
San Jose, CA Standard AHJ
San Jose Fire Department (SJFD) - Bureau of Fire Prevention
Enclosed Tent
> 400 sq ft
Open Canopy
> 700 sq ft
Code
California Fire Code with San Jose Municipal Code Amendments
Sacramento, CA Standard AHJ
Sacramento Fire Department - Fire Prevention Division
Enclosed Tent
> 400 sq ft
Open Canopy
> 700 sq ft
Code
2022 California Fire Code with Sacramento Local Amendments
New York City, NY PE/RA Stamp
NYC Department of Buildings (DOB) & FDNY Bureau of Fire Prevention
Enclosed Tent
> 400 sq ft
Open Canopy
> 400 sq ft
Code
2022 NYC Fire Code & 2022 NYC Building Code
Chicago, IL PE/RA Stamp
Chicago Department of Buildings (DOB) & Chicago Fire Department (CFD)
Enclosed Tent
> 400 sq ft
Open Canopy
> 400 sq ft
Code
Chicago Construction Codes (Title 14A/14B/14F, 2018 IBC/IFC-based)
Miami-Dade, FL PE/RA Stamp
Miami-Dade Fire Rescue (MDFR) & Department of Regulatory and Economic Resources (RER)
Enclosed Tent
> 120 sq ft
Open Canopy
> 120 sq ft
Code
Florida Building Code (HVHZ) & Florida Fire Prevention Code (8th Ed. NFPA 1/101)

AHJ Review & Licensed PE/Architect Stamp Scope

7 Verified PE/RA Stamp Cities

Most US Fire Marshals accept scaled event floor plans prepared by event planners, tent contractors, or venue managers when accompanied by occupant load math and NFPA 701 flame certificates. However, EgressCAD is drafting and compliance-checking software and does not affix a licensed Professional Engineer (PE) or Registered Architect (RA) seal. In the 7 verified jurisdictions below, local rules mandate a state-licensed PE or RA stamp above specified size or occupant thresholds. You can export the EgressCAD .DXF and hand it directly to a local engineer or architect to review and seal: