Compliant Architectural Schematic (90' x 60')

Scale ref: 1/8" = 1'-0" | Governing Load: 360 occ | Status: FAIL
8/9 CHECKS PASS
90'-0"60'-0"T1T2T3T4T5T6T7T8T9T10T11T12T13T14T15T16T17T18T19T20T21T22T23T24T25T26T27T28T29T30T31T32T33T34T35FEFEEX-1 (72")EX-2 (72")
Egress Exit & Worst-Case Path (73.0 ft / 200 ft max) 2A:10BC Extinguisher (75 ft radius) 60" Round Table (8 seats, 11.5 ft OC)
Banquet (60" Rounds)
280 seats
35 tables at 8 guests each (15 sq ft net)
Ceremony / Theater Chairs
655 seats
IFC Table 1004.5 concentrated chairs (7 sq ft net)
Standing Cocktail
972 guests
IFC Table 1004.5 standing space (5 sq ft net)

IFC Exit & Fire Safety Requirements Table

RequirementCode ReferenceMinimum RequiredThis Layout
Governing Occupant LoadIFC 2021 Table 1004.515 sq ft / person360 occupants
Minimum Number of ExitsIFC 1006.2.12 remote exits2 exits placed
Minimum Width per ExitIFC 1010.1.136" clear144" total provided
Maximum Egress Travel DistanceIFC Table 1017.2<= 200 ft73.0 ft worst-case
2A:10BC Fire ExtinguishersIFC 3107.9 / NFPA 1075 ft max travel2 unit(s)
ADA Wheelchair SpacesIBC Table 1109.2.2.16 spaces36" x 48" clear floor area each

Fire Permit Triggers by City

Indoor assembly floor plan review required at >= 50 occupants (360 computed).

Ready to add your stage, bar, dance floor, and title block?

Open this exact 60' × 90' Trade Show Hall footprint in the interactive EgressCAD studio to place tables, verify aisles, and export a scaled Fire Marshal PDF and DXF.

Customize This 60' × 90' Trade Show Hall & Export Fire Marshal PDF

Frequently Asked Questions

How many people fit in a 60' × 90' Trade Show Hall?

A 60' × 90' Trade Show Hall (5,400 sq ft) holds 280 seated banquet guests at 35 standard 60-inch round tables with compliant 36-inch aisles, up to 655 theater/ceremony chairs (7 sq ft/person), or up to 972 standing cocktail guests (5 sq ft/person).

How many exits are required for a 60' × 90' Trade Show Hall?

Based on a governing occupant load of 360 under 2021 International Fire Code (IFC), a 60' × 90' Trade Show Hall requires at least 2 remote exits with a minimum clear opening of 36 inches each.

Does a 60' × 90' Trade Show Hall require a fire permit?

Indoor assembly floor plan review required at >= 50 occupants (360 computed).

How many fire extinguishers are needed in a 60' × 90' Trade Show Hall?

At least 2 Class 2A:10BC fire extinguisher(s) placed so that maximum travel distance from any point on the floor does not exceed 75 feet (IFC Section 3107.9 / NFPA 10).